300 _a122
504 _aContents Practical To calibrate single range MC & MI analog meters Identification of Parts of PMMC Meter Service the Defects in MI Type Meters Extend the Range of a MC Meter Trace the internal circuit of an analog multimeter General Maintenance of Analog Multimeters Analog Multimeter Measurement and fuse replacement Identification of the Digital Multimeters To check and adjust PM2518/02 & PM2618 & PM2718/02 Electronic Calibration General Maintenance of Digital Multimeters Identification of external controls, switches, sockets of a typical Function Generator Identification of internal components/ blocks of a Function Generator Identification of external controls, switches, sockets of a typical Signal Generator Identification of Internal components/ blocks of a Signal Generator Set up a CRO to measure various parameters of a Test Signal Monitor the waveform by triggering the CRO with external trigger Identification of major internal blocks/ components/parts of a CRO Servicing CRO with the Complaint "Dead Set" Servicing CRO with the Complaint No trace' Servicing CRO with the complaint 'No display of signal' Servicing CRO with the complaint No spot on CRO and unstable waveform display' Theory Single Range Analog meters and it's Calibration DC Voltage and current measuring instrument Movements (MC type meters) Moving iron type voltage and current measuring instrument Movements Extending the range and conversions of MC type meters Multirange meters/ multimeters General defects in analog multimeters and its maintenance Identification of Digital Multimeter Characteristics of Digital Multimeter Function Generator Identification of front Panel Controls and Blocks of a Typical Signal Generator CRO Controls and Synchronisation CRO Fundamental Blocks Troubleshooting CRO with the Complaint 'Dead Set' Troubleshooting CRO with the complaint 'No trace on Screen' Troubleshooting CRO with the complaint 'No display of input signal in one Channel' Troubleshooting CRO with the complaint 'No illuminated spot'
650 _aElectronics : Modular Employable Skills
700 _aDGT, MSDE, Govt of India
942 _2ddc
_cBK